For constant monitoring of temperature distribution
Installation type thermal image sensor corresponding to network
Equipped with an external alarm output function
Measuring and Monitoring Temperature from a Wide Field of View
The TP Series of compact thermal image sensors are installed thermal image sensors with superior versatility, equipped with a 2000 pixel infrared detection element in a compact body.
Models that support alarm output and analog output can be used in various fields that utilize temperature data, such as temperature abnormality detection in an area, temperature changes in various lines and facilities, and trend monitoring.
Installation type thermal image sensor
▼ The temperature distribution measured by the thermal image sensor is displayed in the dedicated application software and saved as thermal image (jpg) or temperature data (CSV).
Prepare models tailored to the measurement target
▼ Measurement Range 100~800°C Specifications For High Temperature Measurement
Dust-Proof/Drip-Proof Structure IP65
▼ By using the dedicated cable and fixing screw supplied with the thermal image sensor, it conforms to the dustproof and drip-proof structure IP65.
Variety of Accessories
▼ Accessories include a protective case for thermal imaging sensors, a water-cooled case, and a 4.5 μm band-pass filter for flame detection.
Alarm judgment and alarm output functions
▼ When the alarm determination condition is satisfied in the alarm determination area arbitrarily set in the thermal image, alarm output (no voltage contact) is performed from the main body. You can also save a thermal image when an alarm occurs.
▼ Equipped with two warning contact outputs
▼ Can be used as a thermal image switch.
▼ alarm settings
▼ Output pattern (auto reset/self hold)
▼ Output logical selection (Contact A, Contact B)
Specification
Temperature measurement range: 100~800°C
Communication interface: Ethernet (10BASE-T/100BASE-TX)
Frame time: 3 Hz (1 Hz for alarm output)
Temperature resolution: 0.5°C (in 100°C black body)
Accuracy rating (at ambient temperature 25 +/- 2 deg. C): +/- 2% of the measured value or +/- 3 deg. C, whichever is greater.
Reproducibility: 0.3°C
Detector: Thermopile 2000 pixels
Measurement wavelength: Center wavelength 10 μm
Measuring viewing angle: 25° x 25°
Spatial resolution: 9.1 mrad
focus: fixed focus
Emissivity Correction: 0.10~1.00 (0.01 steps)
Number of contact outputs: 2 points (no voltage contact output)