Bio-Rad TC20 自動細胞計數器 (TC20 Automated Cell Counter)

Bio-Rad TC20 Automated Cell Counter, with / without Thermal Label Printer
詢價商品請諮詢取得報價及交期
商品包含 2 種型號,請點選「立即選購規格」挑選

💡 重要通知:

因中東戰爭造成原物料波動影響,若訂單成立後進貨成本發生重大異動,我們將主動聯繫您協商處理。造成不便,敬請見諒。

登入即享專屬優惠價格
付款月結報帳 / 信用卡 / 銀行轉帳
運送宅配快速到貨,滿 NT$ 999 元即享免運!

選購型號

共 2 個型號
此商品所有型號都需詢價,請按「訂購諮詢」取得報價及交期
TC20 自動細胞計數器 (TC20 Automated Cell Counter) 含影印機
原廠型號 1450103
說明含熱感應影印機
諮詢/訂購後通知
組
商品型號IACJS0019-145102EA
TC20 自動細胞計數器 (TC20 Automated Cell Counter)
原廠型號 1450102
說明-
諮詢/訂購後通知
台
篩選型號
取消

包裝

說明


商品介紹

『商品說明』

The TC20 automated cell counter counts mammalian cells in one simple step using its innovative auto-focus technology and sophisticated cell counting algorithm to produce accurate cell counts in less than 30 seconds. Upon insertion of a counting slide, the TC20 cell counter rapidly provides a total cell count (with or without trypan blue staining) and assesses cell viability via trypan blue exclusion..

Key Features and Benefits

  • Compatible with a broad range of cell sizes and types — counts cell lines, primary cells (from tissue or blood), and stem cells
  • Innovative auto-focus technology — removes the variation associated with manual focusing and leads to precise cell counts in 30 seconds
  • Cell size gates — user selects a population of interest in complex samples, such as primary cells, or lets the cell counting algorithm do all the work
  • Cell viability — analyzes cells accurately using multifocal plane analysis
  • Easy to archive and analyze — stores up to 100 counts in the onboard memory for access any time, or use the optional TC20 data analyzer software on your PC to further analyze exported cell images

Getting all the data you need about your cell cultures is fast and easy; the TC20 cell counter and disposable counting slides eliminate the need for tedious setup, cleaning, or maintenance. The TC20 cell counter is simple and intuitive to use — learn to use the TC20 automated cell counter in the introduction video or take a virtual test drive.

 

LoadInsertView results 
Load the sample onto a slide.Insert the slide into the TC20 cell counter; counting automatically begins.Obtain a total cell count (without trypan blue) or total and live cell counts (with trypan blue) in 30 seconds.

 

The TC20 automated cell counter has replaced the TC10 automated cell counter. If you own the TC10 automated cell counter, please visit the Accessories tab on this page to order additional kits, reagents, and accessories for your ongoing work using the TC10 cell counter. Please note that all accessories are compatible with both the TC20 and TC10 automated cell counters.

Get Accurate and Reproducible Results

The TC20 automated cell counter uses microscopy with auto-focus that analyzes multiple focal planes to identify the best plane. Without requiring any user input, the sophisticated cell counting algorithm uses the image acquired from the best focal plane to identify cells and exclude debris, thereby calculating the total cell count. The auto-focus leads to highly reproducible cell counts with reduced user-to-user variability compared to a hemocytometer and cell counters with manual focus. Using auto-focus instead of subjective manual focusing is especially important when assessing cell viability because an incorrectly selected focal plane will lead to inaccurate results.

Unlike cell counters based on electrical impedance (Coulter principle), the TC20 image-based analysis allows the user to view the cells in real time, providing visual proof that the TC20 cell counter has correctly identified cells.

The TC20 automated cell counter provides accuracy comparable to results obtained with a hemocytometer. It can count cells with a 6–50 μm cell diameter and within a broad concentration range of 5 x 104–1 x 107 cells/ml, which eliminates the need to dilute cells, thus reducing errors associated with sample dilutions prior to counting. Read more about how the TC20 compares to a hemocytometer.

This automated counter uses disposable counting slides with a patent-pending design that ensures even distribution of cells throughout the counting chamber, regardless of the user's pipetting style, allowing every user to accurately and consistently count cells.

For complex samples composed of multiple cell populations, such as primary cells, users can adjust the cell size gates to define the population of interest that will be counted. When counting multiple sample replicates, the TC20 automated cell counter can save the position of the cell size gates and apply them to subsequent counts.

When user-defined gates are enabled you can select a population of interest by adjusting the position of the cell size gates.

Cell Viability

The TC20 automated cell counter uses multifocal plane analysis to assess cell viability. The conventional method of analyzing viability using a single focal plane can lead to inaccurate conclusions because light scattering and the alignment of cells at different heights in a counting chamber can change the appearance of cells — live cells may appear to be dead and vice versa. To determine whether cells are viable, the TC20 counter analyzes each cell using images acquired from multiple focal planes during the focusing step. Find out more about the advantages of multifocal plane analysis.

Minimize Your Sample Preparation

The broad concentration range of the TC20 automated cell counter eliminates the need to dilute cells prior to counting, reducing the errors associated with sample dilutions that may be necessary when counting cells by other methods. The counting algorithm discriminates and counts individual cells within clusters of up to five cells, providing accurate counts without the need to extensively declump cells prior to loading.


『商品規格』

Counting time, sec
30
Cell concentration range, cells/ml
5 x 104–1 x 107
Optimal cell concentration range, cells/ml
1 x 105–5 x 106
Cell diameter range, µm
6–50
Sample volume, µl
10
Data storage, counts
100
Data export
Via USB flash drive
Printer connectivity
Yes
Dilution calculator
Yes
Image of cells available
Yes
Dimensions (W x D x H), cm (in)
19 x 15 x 25.4 (7.5 x 6 x 10)
Weight without the external power supply, kg (lb)
2.2 (4.8)
Counting time, sec
30
Cell concentration range, cells/ml
5 x 104–1 x 107
Optimal cell concentration range, cells/ml
1 x 105–5 x 106
Cell diameter range, µm
6–50
Sample volume, µl
10
Data storage, counts
100
Data export
Via USB flash drive
Printer connectivity
Yes
Dilution calculator
Yes
Image of cells available
Yes
Dimensions (W x D x H), cm (in)
19 x 15 x 25.4 (7.5 x 6 x 10)
Weight without the external power supply, kg (lb)
2.2 (4.8)
Counting time, sec
30
Cell concentration range, cells/ml
5 x 104–1 x 107
Optimal cell concentration range, cells/ml
1 x 105–5 x 106
Cell diameter range, µm
6–50
Sample volume, µl
10
Data storage, counts
100
Data export
Via USB flash drive
Printer connectivity
Yes
Dilution calculator
Yes
Image of cells available
Yes
Dimensions (W x D x H), cm (in)
19 x 15 x 25.4 (7.5 x 6 x 10)
Weight without the external power supply, kg (lb)
2.2 (4.8)
Counting time, sec
30
Cell concentration range, cells/ml
5 x 104–1 x 107
Optimal cell concentration range, cells/ml
1 x 105–5 x 106
Cell diameter range, µm
6–50
Sample volume, µl
10
Data storage, counts
100
Data export
Via USB flash drive
Printer connectivity
Yes
Dilution calculator
Yes
Image of cells available
Yes
Dimensions (W x D x H), cm (in)
19 x 15 x 25.4 (7.5 x 6 x 10)
Weight without the external power supply, kg (lb)
2.2 (4.8)
以上圖片及相關資訊由 Bio-Rad 提供。
若有現場安裝、說明或特殊配送需求,歡迎事前與科研市集聯繫。部分商品因供應條件限制,可能無法提供相關服務,敬請見諒。

商品資訊

有任何商品上面的問題?
別擔心,讓科研市集來為你服務!
立即諮詢客服
最懂你的專屬採購模式
需要單位的最優價格及服務嗎? 我們的專業團隊能幫到你!
前往了解方案