The XYZ axis can be used to determine the direction in which an impact such as a fall or collision is applied.
You can bring it on the plane.
Setting, measuring, recording and checking can be done just by bringing the device close to the NFC communication reader (a FeliCa port equipped personal computer is required separately).
Specifications
Measurement item: Shock, temperature, humidity
Temperature measuring range: 40 to + 80 ℃
Humidity measurement range: 0 to 99%
Shock measurement range: 5 to 125g
Temperature Resolution: 0.1 ℃
Humidity Resolution: 1%
Shock Resolution: 1G
Temperature accuracy: ±0.3 ℃ (-10 to + 50 ℃)/±0.5 ℃ (Others)
Accuracy of humidity: ±5% (to 45 ℃)
Impact accuracy: ±15%
Temperature measurement interval : 1 to 255 minutes
Humidity measurement interval : 1 to 60 seconds 1 to 255 minutes
Impact Measurement interval : Every time an impact is detected above the threshold value
Temperature memory: 14000 items
Humidity Memory: 14000
Impact memory: 2000 each for XYZ axes
Interface: NFC Communications
Supported OS: Windows (R) 7/8/10
Power supply : CR 2477 lithium battery x 1 piece (attachment)