Non-contact voltage detection function (NCV function) is included. When the upper part of the product is moved within 8 mm, the NCV indicator light will light to indicate that there is an AC voltage source nearby.
It has auto range function, display hold function, sleep function, continuity check function, duty ratio measurement function, frequency measurement function, diode test function, capacitor capacitance measurement function, and backlight function.
The back of the protective cover has a test lead slot for storing the test lead.
Specification
Display: 3999 count LCD
Measurement and detection items: DC voltage, AC voltage, DC current, AC current, resistance, frequency, continuity check, duty ratio, capacitor, diode check, non-contact voltage detection (NCV function)
Measurement Range (* Maximum Accuracy) DC Voltage: 400 m/4/40/400/600V *± (0.5%%%%rdg+5dgts)
Measurement Range (* Maximum Accuracy) AC Voltage: 4/40/400/600V *± (1.2%%%%rdg+5dgts)
Measurement Range (* Maximum Accuracy) DC Current: 400μ/4000μ/40 m/400 mA *± (1.8%%%%rdg+5dgts)
Measurement Range (* Maximum Accuracy) AC Current: 400μ/4000μ/40 m/400 mA *± (2.0%%%%rdg+8dgts)
Measurement Range (* Maximum Accuracy) Resistance: 400/4k/40k/400k/4M/40 MΩ *± (1.0%%%%rdg+5dgts)
Measurement Range (* Maximum Accuracy) Frequency: 5/50/500/5k/50k/500k *± (0.1%%%%rdg+5dgts)
Diode Check: Measure the forward voltage of the diode
Conductivity check: Alarm (buzzer) sound sounds at approximately 10 Ω or less.
Non-contact voltage detection function (NCV function): AC voltage source 100 V/50-60 Hz detected (AC voltage source within 8 mm from the top of the main unit)
Maximum input voltage: DCV 600VDC, ACV 600Vrms
Maximum input current: 400 mA (mA range), 4000 μA (μA range)
Input Impedance: Approx. 10 MΩ or More (DC/AC Voltage Range)
Sampling rate: 4 times/second
Power supply/Battery life: 2 AAA batteries/150 hours
External dimensions/mass: 112 (W) x 35 (H) x 58 (D) mm/approx. 180 g (including battery)