Measurement by inserting a rod-shaped sensor into a pile of wood chips used as biomass fuel
Equipped with calibration curves for cutting and crushing chips
User calibration curve can be created
Equipped with upper alarm and moisture value correction function
Specification
Measurement Method: Electrical Resistance
Measuring object: cutting tip, grinding tip
Measuring range: 15~55%%%% (wet base)
Measurement accuracy:
▼ Cutting Tip: Standard Error 5.0%%%%, Repeated Accuracy 2.0%%%%
▼ Crushing Tip: Standard Error 3.0%%%%, Repeating Accuracy 2.0%%%%
▼ Standard method: 103°C constant weight method (based on JIS Z 2109: 2009)
Display Method: Digital (LCD, Minimum Display Digit 0.1%%%%)
Operating Temperature Range: 0~40°C (No Condensation)
Functions: Upper alarm (15~55%%%% or off), Average value display, Water value correction (±9.9%%%%), Auto power off, Continuous measurement mode, Calibration curve memory (13 types)
Power Supply: 1.5 V Battery (AA Alkali) x 6
Power consumption: 0.54 W
Dimensions and mass:
▼ Body: 110 (W) x 210 (D) x 50 (H) mm, 0.5 kg
▼ Bar sensor (excluding cable): 176 (W) x 705 (D) x 45 (H) mm, 1.3 kg