Concrete (Maximum detection depth: 200 mm metal, 80 mm non-metal) Detects objects in dry concrete.
Detects objects (metal) in wet concrete (maximum detection depth: 60 mm metal) that are not dry.
Brick (maximum depth of detection: 80 mm) Solid brick or single wall for metal, electrical wiring, plastic pipes, etc.
Gypsum board (Maximum detection depth: 38 mm for wood, 80 mm for non-wood) Detects wood, electrical wiring, and metal in wood or gypsum board.
Piped floor heating (maximum detection depth: 80 mm) Detects plastic pipes, metal, and other water in the floor of piped floor heating.
Vertical coring brick (maximum detection depth: 80 mm) Detects objects in a brick with many vertical holes (cavities).
Horizontal coring brick (maximum detection depth: 80 mm) Detects objects in a brick with many horizontal holes (cavities).
Four display views according to the application
Object view Displays detection depth, object material, and distance between objects
Spot view Ideal for detection in corners and confined spaces
2D signal view Displays detection object signal strength and depth
Signal view Displays detection object signal strength by waveform height
Color-coded detection object material. Color Display
Software is available for free download
Convenient data transfer screenshot function and quick transfer via USB-C/micro-SD card to save detection screen to PC
Forged and advanced in the field, 4th generation is now available! The color display shows the detection result and the material easily. Easily store and transfer detection images to PC, making it easier to use and safer!
Specifications
Model number: D-TECT 200 JPS
Detection capacity: 200 mm (subject to conditions)
Measurement accuracy: Center part: +/-5 mm
Dustproof and waterproof: IP5X
Power supply: 4 AA batteries (included) or 10.8 V DC lithium-ion batteries (2.0 Ah) (included)
Size: 106 (W) x 112 (D) x 231 (H) mm
Weight: 690 g
Accessories: 1 lithium-ion battery, charger, alkaline battery holder, 4 AA batteries, hand strap, USB Type-C cable, carrying case
Operating temperature range: - 10 ~ 50 degrees C
Continuous usage time: AA battery: About 2 hours
Minimum measurement interval: 40 mm
Maximum measurement range: 200 mm (metal in dry concrete)
Depth accuracy: Dried concrete: +/- 5 mm Wet concrete: +/- 10 mm
Storage temperature range: - 20 ~ 70 C
Material: Polyamide resin
Applications: - Detection of reinforcing bars embedded in concrete, plastic pipes, wiring and lumber behind walls, and selection of drilling locations and depths