TOKYO RIKAKIKAI CO., LTD. 食物過敏原,農藥殘留物?檢查用振盪器 MMS-3021 MMS-3021
Food allergens, pesticide residues? Shaker for inspection MMS-3021
商品包含多種型號及規格,請點選「立即選購規格」挑選
付款方式
月結報帳 / 信用卡 / 銀行轉帳
運送方式
宅配快速到貨,滿 NT$ 999 元即享免運!
選購型號
商品介紹
Feature
Allergens and Pesticide Residues: Foods containing certain ingredients (Eggs, milk, wheat, buckwheat, peanuts) in the pre-treatment for ELISA measurement may cause allergies and are required to be labeled. In addition, the distribution of agricultural chemicals remaining in food is prohibited unless they are below the permissible limit. For the measurement of specific raw materials, it is obligatory to use the modified ELISA test kits of Morinaga Institute of Science Inc. and Nippon Ham Co., Ltd. In addition, in the field of environmental analysis, immunoassays are specified by JIS standards, and the pesticide residue measurement kit from Horiba Corporation is suitable for rapid testing of agricultural products by immunoassay.
This is a dedicated shaker for shaking and extracting samples using a food allergen (modified) specific raw material/pesticide residue ELISA measurement kit.
50 mL Centrifuge Tube x 24 Shake Table is included. When the number of samples is large, up to 48 centrifuge tubes can be installed and extracted by using a shaking table for 2 stacks (optional).
Setting and displaying the shaking speed can be performed digitally, and highly reproducible extraction operations can be performed under the same shaking conditions.
Displays the total shaking time. The elapsed time of shake extraction can be confirmed, and highly reproducible extraction operation can be performed at the same shake time.
The extraction operation of improved specified raw materials requires shaking at room temperature for more than 12 hours. An optional FMC-1000 type low-temperature thermostatic chamber is available that is designed specifically for use during the day and night.
Timer function is provided as standard. You can select from the Auto Stop function (Countdown/Countup) and the accumulated time, and the shake state can be managed according to the time.
Specifications
Shaking method: Round trip
Performance:
Shaking speed and amplitude: 20 ~ 250 rpm, 30 mm
Features:
Shaking speed setting and display: Encoder type digital setting and digital display
Safety features: Fuse, motor overload protection circuit
Included features: Auto-stop (countdown/countup) or integrated time selection (1 min to 999 h), power outage recovery
Standard:
Shaking table: For 24 50 mL centrifuge tubes
Operating ambient temperature range: 4 ~ 50 degrees C
External dimensions (mm): 456 W x 379 D x 185 H
Mass: About 22 kg
Power input/voltage: 0.3 A/100 VAC 50/60 Hz
*Performance is measured at room temperature of 20 degrees Celsius, rated supply voltage, 50 Hz and no load.
*Shaking speed should be within the range indicated by the measuring kit.